{"product_id":"victron-energy-orion-tr-24-12-30a-360w-isolated-dc-dc-converter","title":"Victron Energy Orion-Tr 24\/12-30A 360W | Isolated DC-DC Converter","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe Victron Energy Orion-Tr 24\/12-30A is a fully isolated 360W DC-DC converter designed for professional power conversion in demanding marine, mobile, and industrial applications.\u003c\/p\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e 200VDC isolation between input, output, and case eliminates ground loops and protects sensitive connected equipment.\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e A low-power switch or engine run\/stop signal controls the unit remotely, removing the need for high-current input switching.\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eParalleling Capability\u003c\/strong\u003e An unlimited number of units can be connected in parallel to increase output current for larger system requirements.\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eAdjustable Output Voltage\u003c\/strong\u003e Output is field-adjustable from 10–15V to match specific system voltage requirements without additional components.\u003c\/li\u003e\n\u003cli class=\"whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eHigh Temperature Protection\u003c\/strong\u003e Output current automatically reduces at elevated ambient temperatures to prevent thermal damage and ensure continuous operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe Orion-Tr 24\/12-30A delivers 30A continuous output at 40°C from a 16–35VDC input, with a peak short circuit output current of 60A and 88% efficiency. Its tool-free screw terminal design simplifies installation across professional system builds.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWith an operating range of -20°C to +55°C and humidity tolerance up to 95% non-condensing, this unit is built for the harshest real-world environments. IP43 protection is achieved when installed with screw terminals oriented downward.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eCertified to EN 60950, EN 61000-6-3, EN 55014-1, EN 61000-6-2, and ECE R10-5 automotive directive standards, the Orion-Tr 24\/12-30A meets rigorous international safety, emission, and immunity requirements for professional-grade DC power systems.\u003c\/p\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e16–35VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eUnder Voltage Shutdown\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e14V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eUnder Voltage Restart\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e15V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e12.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOutput Voltage Adjust Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e10–15V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOutput Voltage Tolerance\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e±0.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOutput Noise\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e2mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eContinuous Output Current at 40°C\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMaximum Output Current (10s)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eShort Circuit Output Current\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eContinuous Output Power at 25°C\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e430W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eContinuous Output Power at 40°C\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e360W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eNo Load Input Current\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u0026lt;100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCurrent Consumption (Disabled)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e\u0026lt;200µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e200VDC (input, output, and case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e-20 to +55°C (derate 3%\/°C above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eHumidity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMax. 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDC Connection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMaximum Cable Cross-Section\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e16mm² (AWG6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e4 lbs (1.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSafety Standard\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eEmission Standard\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eImmunity Standard\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAutomotive Directive\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":53715621380406,"sku":"ORI241240110","price":201.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Orioni241240110.jpg?v=1771631445","url":"https:\/\/thesolarstore.com\/products\/victron-energy-orion-tr-24-12-30a-360w-isolated-dc-dc-converter","provider":"The Solar Store","version":"1.0","type":"link"}