{"product_id":"solar-rackworks-top-of-pole-mount-for-12-modules-type-24-41-81","title":"Top-of-Pole Mount for 12 Large Modules 360W to 460W (39-48\" x 65-81\") | Solar Rackworks","description":"\u003ch2 data-start=\"300\" data-end=\"315\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"317\" data-end=\"800\"\u003e\n\u003cli data-start=\"317\" data-end=\"440\"\u003e\n\u003cp data-start=\"319\" data-end=\"440\"\u003eSupports \u003cstrong data-start=\"328\" data-end=\"362\"\u003e12 Type‑24 Modules (41″ × 81″)\u003c\/strong\u003e using factory‑provided holes for bottom mounting—no custom adapters needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"441\" data-end=\"542\"\u003e\n\u003cp data-start=\"443\" data-end=\"542\"\u003eFull tilt adjustability from \u003cstrong data-start=\"472\" data-end=\"485\"\u003e0° to 60°\u003c\/strong\u003e in \u003cstrong data-start=\"489\" data-end=\"507\"\u003e10° increments\u003c\/strong\u003e for seasonal solar optimization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"543\" data-end=\"675\"\u003e\n\u003cp data-start=\"545\" data-end=\"675\"\u003eStrong build: powder‑coated steel gimbals, galvanized steel strongbacks, and module rails made from 6061‑T6 structural aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"676\" data-end=\"800\"\u003e\n\u003cp data-start=\"678\" data-end=\"800\"\u003eRated for standard wind speeds (≈ 90 mph), with heavy‑duty\/ high‑wind variants available for exposed or high‑wind zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"802\" data-end=\"805\"\u003e\n\u003ch2 data-start=\"807\" data-end=\"829\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"831\" data-end=\"1072\"\u003eThe \u003cstrong data-start=\"835\" data-end=\"907\"\u003eSolar Rackworks Top‑of‑Pole Mount for 12 Modules Type‑24 (41″ × 81″)\u003c\/strong\u003e is engineered for high‑capacity solar arrays. It combines durable materials, module‑specific fit, and adjustable tilt to deliver reliable and efficient performance.\u003c\/p\u003e\n\u003cp data-start=\"1074\" data-end=\"1307\"\u003eThis rack is designed to hold twelve Type‑24 modules and uses the modules’ factory bolt holes for secure, clean attachment. No drilling or custom side brackets required: just align and bolt from the bottom through the existing holes.\u003c\/p\u003e\n\u003cp data-start=\"1309\" data-end=\"1642\"\u003eThe structure uses \u003cstrong data-start=\"1328\" data-end=\"1359\"\u003epowder‑coated steel gimbals\u003c\/strong\u003e for the tilt mechanism, \u003cstrong data-start=\"1384\" data-end=\"1416\"\u003egalvanized steel strongbacks\u003c\/strong\u003e for backbone support, and \u003cstrong data-start=\"1443\" data-end=\"1474\"\u003e6061‑T6 structural aluminum\u003c\/strong\u003e for the rails that support the modules. These materials are selected for their strength, resistance to corrosion, and ability to endure outdoor environmental stresses.\u003c\/p\u003e\n\u003cp data-start=\"1644\" data-end=\"1914\"\u003eTilt adjustments from 0° to 60° allow for seasonal angle changes, improving solar exposure in winter and managing heat in summer. The standard version is engineered for 90 mph wind load; for areas prone to stronger winds, the heavy‑duty variant (≈ 130 mph) is available.\u003c\/p\u003e\n\u003cp data-start=\"1916\" data-end=\"2084\"\u003eAccording to the manufacturer’s published rack‑module compatibility chart, the 12‑module Type‑24 rack is an offered configuration. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.solarrackworks.com\/assets\/sr_top-of-pole-racks-1-12-module.pdf?utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.solarrackworks.com\/assets\/sr_top-of-pole-racks-1-12-module.pdf?utm_source=chatgpt.com\" class=\"flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-full grow truncate overflow-hidden text-center\"\u003eSolar Rack Works\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2086\" data-end=\"2352\"\u003e\u003cstrong data-start=\"2086\" data-end=\"2108\"\u003eInstallation Note:\u003c\/strong\u003e The mounting pole (galvanized steel, Schedule 40 or 80) is \u003cstrong data-start=\"2168\" data-end=\"2184\"\u003enot included\u003c\/strong\u003e. Installer must supply. Also, ensure the pole diameter, wall thickness, and foundation are sufficient for the load (modules + rack + wind) and local code requirements.\u003c\/p\u003e\n\u003chr data-start=\"2354\" data-end=\"2357\"\u003e\n\u003ch2 data-start=\"2359\" data-end=\"2386\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_sk2ct_1\"\u003e\n\u003cdiv class=\"_tableWrapper_sk2ct_13 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2388\" data-end=\"3448\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2388\" data-end=\"2483\"\u003e\n\u003ctr data-start=\"2388\" data-end=\"2483\"\u003e\n\u003cth data-start=\"2388\" data-end=\"2422\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2422\" data-end=\"2483\" data-col-size=\"md\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2582\" data-end=\"3448\"\u003e\n\u003ctr data-start=\"2582\" data-end=\"2678\"\u003e\n\u003ctd data-start=\"2582\" data-end=\"2616\" data-col-size=\"sm\"\u003eModule Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2616\" data-end=\"2678\" data-col-size=\"md\"\u003e12 × Type‑24 (41″ × 81″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2679\" data-end=\"2775\"\u003e\n\u003ctd data-start=\"2679\" data-end=\"2713\" data-col-size=\"sm\"\u003eTilt Adjustment Range\u003c\/td\u003e\n\u003ctd data-start=\"2713\" data-end=\"2775\" data-col-size=\"md\"\u003e0° to 60°, in 10° increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2776\" data-end=\"2871\"\u003e\n\u003ctd data-start=\"2776\" data-end=\"2810\" data-col-size=\"sm\"\u003eGimbal Material\u003c\/td\u003e\n\u003ctd data-start=\"2810\" data-end=\"2871\" data-col-size=\"md\"\u003ePowder‑coated steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2872\" data-end=\"2966\"\u003e\n\u003ctd data-start=\"2872\" data-end=\"2906\" data-col-size=\"sm\"\u003eStrongback Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2906\" data-end=\"2966\"\u003eGalvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2967\" data-end=\"3062\"\u003e\n\u003ctd data-start=\"2967\" data-end=\"3001\" data-col-size=\"sm\"\u003eModule Rail Material\u003c\/td\u003e\n\u003ctd data-start=\"3001\" data-end=\"3062\" data-col-size=\"md\"\u003e6061‑T6 structural aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3063\" data-end=\"3157\"\u003e\n\u003ctd data-start=\"3063\" data-end=\"3097\" data-col-size=\"sm\"\u003eWind Load Rating (Standard)\u003c\/td\u003e\n\u003ctd data-start=\"3097\" data-end=\"3157\" data-col-size=\"md\"\u003e~ 90 mph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3158\" data-end=\"3254\"\u003e\n\u003ctd data-start=\"3158\" data-end=\"3193\" data-col-size=\"sm\"\u003eHeavy‑Duty \/ High‑Wind Option\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3193\" data-end=\"3254\"\u003eAvailable (~ 130 mph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3255\" data-end=\"3350\"\u003e\n\u003ctd data-start=\"3255\" data-end=\"3289\" data-col-size=\"sm\"\u003eMounting Method\u003c\/td\u003e\n\u003ctd data-start=\"3289\" data-end=\"3350\" data-col-size=\"md\"\u003eBottom‑bolted via factory module bolt holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3351\" data-end=\"3448\"\u003e\n\u003ctd data-start=\"3351\" data-end=\"3386\" data-col-size=\"sm\"\u003eMounting Pole Requirement\u003c\/td\u003e\n\u003ctd data-start=\"3386\" data-end=\"3448\" data-col-size=\"md\"\u003eInstaller‑supplied galvanized steel pipe (Schedule 40\/80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Solar Rackworks","offers":[{"title":"Default Title","offer_id":53023187239222,"sku":null,"price":4550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/MS_PWF_TP_c4cdb1cd-23ea-443f-bafe-cef0cd8c414b.avif?v=1758308646","url":"https:\/\/thesolarstore.com\/products\/solar-rackworks-top-of-pole-mount-for-12-modules-type-24-41-81","provider":"The Solar Store","version":"1.0","type":"link"}