{"title":"Electrical Accessories","description":"\u003ch2\u003eElectrical Accessories\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eExposed wire can pick up surges from lightning, installing Surge Protection in your system can reduce damage to sensitive equipment. \u003c\/p\u003e\n\u003cp\u003eProperly sized Wire \u0026amp; Cable is important in any electrical system for efficient and safe transfer of electrical energy, we stock specific wiring for PV arrays and battery cables.\u003c\/p\u003e\n\u003cp\u003eGround Fault Protection using PV Ground Fault Breakers will disconnect the solar array if a ground fault occurs in the wiring. \u003c\/p\u003e","products":[{"product_id":"outback-fwpv8-flexware-pv-combiner-box","title":"Outback FWPV8 Flexware PV Combiner Box","description":"\u003cdiv class=\"story\"\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cstrong\u003e\u003cfont\u003eOutback FLEXware PV Combiner (FWPV8)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cfont\u003eThe FLEXware PV8 and FLEXware PV12 accommodate overcurrent protection requirements for off-grid and grid-connected applications. The DIN rail can be fitted with 150VDC circuit breakers for low-voltage PV arrays or 600VDC fuse holders for grid-tie arrays. These combiners replace the PSPV.\u003c\/font\u003e\u003c\/p\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cfont\u003eRated for NEMA-3R rainproof, the powder-coated aluminum chassis can be mounted on a wall, a sloped roof, or a pole.\u003c\/font\u003e\u003c\/p\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cfont\u003eDual output lugs allow connection for up to 2\/0 AWG wire. An easily removable flame-retardant polycarbonate deadfront panel prevents accidental contact with live terminals. FWPV8 has one circuit and FWPV12 can be configured to have one or two circuits. Negative and ground terminal bus bars are included.\u003c\/font\u003e\u003c\/p\u003e\n\n\t\u003cp\u003e\n\n\t\t \u003c\/p\u003e\n\n\t\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\n\t\t\u003ctbody\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\t\u003cstrong\u003e\u003cfont\u003eOutBack model\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\t\u003cstrong\u003e\u003cfont\u003e# of breakers\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\t\u003cstrong\u003e\u003cfont\u003e# of fuse holders\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\t\u003cstrong\u003e\u003cfont\u003eDimensions (in)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\t\u003cstrong\u003e\u003cfont\u003eWeight (lbs)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\t\u003cstrong\u003e\u003cfont\u003eItem code\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003eFWPV8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e15.2 x 9.2 x 3.9\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e4.4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-item-code\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e053-03012\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003eFWPV12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e15.2 x 12.7 x 3.9\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-text\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e5.9\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-item-code\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e053-03014\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\u003c\/tbody\u003e\n\n\t\u003c\/table\u003e\n\n\t\u003cp\u003e\n\n\t\t \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"The Solar Store","offers":[{"title":"Default Title","offer_id":51347855343926,"sku":"053-03012","price":230.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/ED_AC_OBP.jpg?v=1732917417"},{"product_id":"midnite-mnbcb-1000-100-battery-combiner","title":"Midnite MNBCB-1000\/100 Battery Combiner","description":"\u003cdiv class=\"story\"\u003e\n\u003ch1 class=\"main-text\"\u003e\u003cspan style=\"font-size: 22px;\"\u003e\u003cspan style=\"color: #333333;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-style: normal;\"\u003e\u003cspan style=\"font-variant-ligatures: normal;\"\u003e\u003cspan style=\"font-variant-caps: normal;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"letter-spacing: normal;\"\u003e\u003cspan style=\"orphans: 2;\"\u003e\u003cspan style=\"text-transform: none;\"\u003e\u003cspan style=\"white-space: normal;\"\u003e\u003cspan style=\"widows: 2;\"\u003e\u003cspan style=\"word-spacing: 0px;\"\u003e\u003cspan style=\"background-color: #ffffff;\"\u003e\u003cspan style=\"text-decoration-style: initial;\"\u003e\u003cspan style=\"text-decoration-color: initial;\"\u003e\u003cspan\u003eMidnite MNBCB-1000\/100 Battery Combiner\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv style=\"text-align: start; -webkit-text-stroke-width: 0px;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003cspan style=\"color: #333333;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-style: normal;\"\u003e\u003cspan style=\"font-variant-ligatures: normal;\"\u003e\u003cspan style=\"font-variant-caps: normal;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"letter-spacing: normal;\"\u003e\u003cspan style=\"orphans: 2;\"\u003e\u003cspan style=\"text-transform: none;\"\u003e\u003cspan style=\"white-space: normal;\"\u003e\u003cspan style=\"widows: 2;\"\u003e\u003cspan style=\"word-spacing: 0px;\"\u003e\u003cspan style=\"background-color: #ffffff;\"\u003e\u003cspan style=\"text-decoration-style: initial;\"\u003e\u003cspan style=\"text-decoration-color: initial;\"\u003e\u003cspan\u003eThe \u003cb\u003eMNBCB-1000\/100\u003c\/b\u003e Battery Combiner can be used to combine circuits from multiple inverters or \u003cspan style=\"font-size: 12.96px;\"\u003ebattery strings or both. There are spaces for six large 175 A or 250 A breakers on both ends. 35.5” W x \u003c\/span\u003e\u003cspan style=\"font-size: 12.96px;\"\u003e22”H x 9.75”D, and weighs 50 lbs. \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start; -webkit-text-stroke-width: 0px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start; -webkit-text-stroke-width: 0px;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003cspan style=\"color: #333333;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-style: normal;\"\u003e\u003cspan style=\"font-variant-ligatures: normal;\"\u003e\u003cspan style=\"font-variant-caps: normal;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"letter-spacing: normal;\"\u003e\u003cspan style=\"orphans: 2;\"\u003e\u003cspan style=\"text-transform: none;\"\u003e\u003cspan style=\"white-space: normal;\"\u003e\u003cspan style=\"widows: 2;\"\u003e\u003cspan style=\"word-spacing: 0px;\"\u003e\u003cspan style=\"background-color: #ffffff;\"\u003e\u003cspan style=\"text-decoration-style: initial;\"\u003e\u003cspan style=\"text-decoration-color: initial;\"\u003e\u003cspan\u003e\u003cspan style=\"font-size: 12.96px;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start; -webkit-text-stroke-width: 0px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start; -webkit-text-stroke-width: 0px;\"\u003e\n\u003ctable border=\"0\" cellpadding=\"5\" cellspacing=\"0\" width=\"60%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e50.0 LB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMNBCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd\u003eMNBCB 1000\/100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eCombiner for multiple inverters or battery strings w\/ 1,000 A 100 mv shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eLong Description\u003c\/td\u003e\n\u003ctd\u003eIncludes 1,000 A Positive and Negative bus bar with 3\/8\" studs. Cables can be double lugged and bus bar can be drilled for additional mounting locations. Includes a 1000amp 50mv Shunt with 1\/2 inch bolt for customer connection. Not for use with SMA!\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eNEMA Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 1 (indoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eNumber of Spaces\u003c\/td\u003e\n\u003ctd\u003e12.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eBus Rating\u003c\/td\u003e\n\u003ctd\u003e1000.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"25px\" width=\"35%\"\u003eMax Wire(main lug)\u003c\/td\u003e\n\u003ctd\u003e4\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347856523574,"sku":"034-00006","price":839.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/1000-100_100_collage_web.jpg?v=1750798093"},{"product_id":"outback-flexnet-dc-advanced-system-monitor","title":"Outback FLEXnet DC Advanced System Monitor (requires a MATE3)","description":"\u003cp\u003e\u003cfont\u003e\u003cstrong\u003eOutback FLEXnet DC System Monitor\u003c\/strong\u003e\u003c\/font\u003e\u003cfont\u003e  \u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cdiv class=\"story\"\u003e\n\n\u003cp\u003e\u003cfont\u003eThe FLEXnet DC System Monitor integrates with an OutBack MATE communications device, providing you with the data you need concerning your system’s health, performance and efficiency. Easily see your system’s current condition with this at-a-glance display. This screen shows current state-of-charge and whether you are currently charging or discharging your batteries. It monitors the amount of power your system is currently producing and consuming as well as the amount of power going IN and OUT of your battery bank. It allows the Mate to display real-time production monitoring of DC sources, such as a solar array or small wind turbine, as well as consumption by loads. It also displays the cumulative energy your system has produced and consumed as well as the total amount of energy that has gone to charging your batteries today. This screen displays today’s lowest state-of-charge and allows you to see how your overall system production compares to system consumption. Review historical energy production and consumption data for the most recent 128 days, including the minimum battery state-of-charge reached for each day. This screen can be used to watch power system production and consumption trends.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003e\u003cimg alt=\"\" class=\"photo_right\" height=\"105\" src=\"http:\/\/www.outbackpower.com\/img\/photos\/product_accessories\/flexnet01.jpg\" width=\"250\"\u003e \u003cstrong\u003eBattery Status Screen\u003c\/strong\u003e - Easily see your system's current condition with this at-a-glance display. This screen shows an easy to interpret \"fuel gauge\" style status bar, current state-of-charge and whether you are currently charging or discharging your batteries. This is useful for those system owners who want a way to quickly understand the current state of their battery bank.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003e\u003cimg alt=\"\" class=\"photo_right\" height=\"105\" src=\"http:\/\/www.outbackpower.com\/img\/photos\/product_accessories\/flexnet02.jpg\" width=\"250\"\u003e \u003cstrong\u003eNow Summary Screen\u003c\/strong\u003e - Monitor the amount of power your system is currently producing and consuming as well as the amount of power going IN and OUT of your battery bank. This screen also displays your battery bank's voltage and current state-of-charge, providing you with real-time production monitoring of DC sources, such as a solar array or small wind turbine, as well as consumption by loads.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003e\u003cimg alt=\"\" class=\"photo_right\" height=\"105\" src=\"http:\/\/www.outbackpower.com\/img\/photos\/product_accessories\/flexnet03.jpg\" width=\"250\"\u003e \u003cstrong\u003eToday Summary Screen\u003c\/strong\u003e - Monitor the cumulative energy your system has produced and consumed as well as the total amount of energy that has gone to charging your batteries today. This screen also displays today's lowest state-of-charge and allows you to see how your overall system production compares to system consumption.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003e\u003cimg alt=\"\" class=\"photo_right\" height=\"105\" src=\"http:\/\/www.outbackpower.com\/img\/photos\/product_accessories\/flexnet04.jpg\" width=\"250\"\u003e \u003cstrong\u003eHistory Summary Screen\u003c\/strong\u003e - Review historical energy production\/consumption data for the most recent 128 days, including the minimum battery state-of-charge reached for each day. This screen can be used to watch power system production and consumption trends.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cdiv class=\"table\"\u003e\n\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"139\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eOutBack model\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"139\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eOutBack MATE system monitor and control\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"139\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eItem code\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMATE\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003eSystem control – shipped with a 50 ft Cat 5 cable\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e030-04180\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMATE-B\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003eBlack version of MATE \u003cspan class=\"page-ref-fixed\"\u003eabove\u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e030-04180-B\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMATE2\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003eFlush-mount version\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e030-04181\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eFlexNet DC\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003eAdvanced DC System Monitor - requires a MATE\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e030-04187\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eHUB-4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003eStacking kit for up to 4 inverters and\/or charge controllers \u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e030-04185\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eHUB-10\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003eStacking kit for up to 10 inverters and\/or charge controllers\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e030-04188\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eRTS\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003eRemote temperature sensor with 20' cable\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e030-04190\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Outback Power","offers":[{"title":"No","offer_id":51358941872438,"sku":"030-04187","price":423.0,"currency_code":"USD","in_stock":true},{"title":"500A","offer_id":51358941905206,"sku":"030-04187","price":446.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/IN-OBP-FLEXnetDC-030-04187.jpg?v=1732917519"},{"product_id":"outback-fwpv-12-pv-combiner-box-for-12-150vdc-breakers-or-8-600vdc","title":"Outback FWPV-12 PV Combiner Box for 12 150VDC breakers or 8 600VDC","description":"\u003cdiv class=\"story\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eOutback FLEXware PV Combiner (FWPV12)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eThe FLEXware PV8 and FLEXware PV12 accommodate overcurrent protection requirements for off-grid and grid-connected applications. The DIN rail can be fitted with 150VDC circuit breakers for low-voltage PV arrays or 600VDC fuse holders for grid-tie arrays. These combiners replace the PSPV.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eRated for NEMA-3R rainproof, the powder-coated aluminum chassis can be mounted on a wall, a sloped roof, or a pole.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eDual output lugs allow connection for up to 2\/0 AWG wire. An easily removable flame-retardant polycarbonate deadfront panel prevents accidental contact with live terminals. FWPV8 has one circuit and FWPV12 can be configured to have one or two circuits. Negative and ground terminal bus bars are included.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eOutBack model\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003e# of breakers\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003e# of fuse holders\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eDimensions (in)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eWeight (lbs)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"120\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eItem code\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eFWPV8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e15.2 x 9.2 x 3.9\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e4.4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03012\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eFWPV12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e15.2 x 12.7 x 3.9\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e5.9\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03014\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Outback Power","offers":[{"title":"Default Title","offer_id":51347868549430,"sku":"053-03014","price":336.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/ED_AC_OBP_30f05277-cb6d-4670-8bcc-78a465654055.jpg?v=1732917551"},{"product_id":"midnite-solar-mnpv3-combiner-box-for-3-150vdc-or-600vdc-breakers","title":"Midnite Solar MNPV3 Combiner Box for 3 150VDC or 600VDC breakers","description":"\u003cdiv class=\"story\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eMidNite Solar PV Combiner (MNPV3)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eThese powder-coated aluminum, NEMA-3R rainproof array combiners will accept 150VDC DIN-rail mounted fuse holders for 600VDC arrays or 150VDC DIN-rail mounted breakers for low-voltage arrays. Dead front. Two sizes. ETL Listed. Negative busbar and ground bar are included. Breakers and fuse holders are not included.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cdiv class=\"table\"\u003e\n\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eMidNite model\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003e# of breakers\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003e# of fuse holders\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eMNPV combiner dimensions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eWeight lbs\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eItem code\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV3\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e3\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e2\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e10.5\" x 5\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e2\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03017\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e13\" x 8\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03018\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e14\" x 9\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03015\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV16\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eN\/A\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e16\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e17\" x 13\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03016\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347868582198,"sku":"053-03017","price":139.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/ED_AC_MNS.jpg?v=1732917551"},{"product_id":"midnite-solar-mnpv6-combiner-box-for-6-150vdc-or-4-600vdc-breakers","title":"Midnite Solar MNPV6 Combiner Box  for 6 150VDC  or 4 600VDC breakers","description":"\u003cdiv class=\"story\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eMidNite Solar PV Combiner (MNPV6)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eThese powder-coated aluminum, NEMA-3R rainproof array combiners will accept 150VDC DIN-rail mounted fuse holders for 600VDC arrays or 150VDC DIN-rail mounted breakers for low-voltage arrays. Dead front. Two sizes. ETL Listed. Negative busbar and ground bar are included. Breakers and fuse holders are not included.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cdiv class=\"table\"\u003e\n\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eMidNite model\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003e# of breakers\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003e# of fuse holders\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eMNPV combiner dimensions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eWeight lbs\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eItem code\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV3\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e3\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e2\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e10.5\" x 5\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e2\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03017\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e13\" x 8\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03018\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e14\" x 9\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03015\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV16\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eN\/A\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e16\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e17\" x 13\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03016\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347868713270,"sku":"053-03018","price":182.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/ED_AC_MNS_13530e83-7b00-4ca9-9109-8891288e5ed8.jpg?v=1732917555"},{"product_id":"midnite-solar-mnpv12-combiner-box-for-12-150vdc-or-10-600vdc-breakers","title":"MidNite Solar MNPV12 Combiner Box  for 12 150VDC or 10 600VDC breakers","description":"\u003cdiv class=\"story\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eMidNite Solar PV Combiner (MNPV12)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eThese powder-coated aluminum, NEMA-3R rainproof array combiners will accept 150VDC DIN-rail mounted fuse holders for 600VDC arrays or 150VDC DIN-rail mounted breakers for low-voltage arrays. Dead front. Two sizes. ETL Listed. Negative busbar and ground bar are included. Breakers and fuse holders are not included.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cdiv class=\"table\"\u003e\n\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eMidNite model\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003e# of breakers\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003e# of fuse holders\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eMNPV combiner dimensions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eWeight lbs\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"111\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eItem code\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV3\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e3\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e2\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e10.5\" x 5\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e2\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03017\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e13\" x 8\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03018\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e14\" x 9\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03015\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eMNPV16\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eN\/A\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e16\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e17\" x 13\" x 3.5\"\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03016\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347868778806,"sku":"053-03015","price":249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/ED_AC_MNS_448bb8e9-f16d-47cb-90cb-3b7bf6cc6145.jpg?v=1732917555"},{"product_id":"din-rail-150vdc-breaker","title":"DIN Rail 150VDC Breaker","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDIN Rail 150VDC Breakers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese DIN rail mounted breakers fit MidNite MNPV and OutBack FWPV combiners. Use breakers for arrays with maximum voltage of 150VDC or less..\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"table\"\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tables-table-head\" bgcolor=\"#ffff33\"\u003e\n\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cspan\u003eAmps\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tables-table-head\" bgcolor=\"#ffff33\"\u003e\n\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cspan\u003eOutBack number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tables-table-head\" bgcolor=\"#ffff33\"\u003e\n\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cspan\u003eMidNite Solar #\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tables-table-head\" bgcolor=\"#ffff33\"\u003e\n\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cspan\u003eItem code\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-1-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03033\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-2-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03034\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-3-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03024\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-4-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03020\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-5-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03025\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-6-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03021\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-8-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03022\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e9\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-9-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV9\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03023\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-10-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03026\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-12-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03027\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e15\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-15-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV15\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03029\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-20-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03030\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-30-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03032\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e40\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-40-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV40\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03039\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e50\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-50-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV50\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03035\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e60\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-60-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV60\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03037\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e63\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eOBB-63-150VDC-DIN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eMNEPV63\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-03038\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePLEASE SPECIFY BREAKER AMPS REQUIRED BELOW.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"1A","offer_id":51358942626102,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"2A","offer_id":51358942658870,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"3A","offer_id":51358942691638,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"4A","offer_id":51358942724406,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"5A","offer_id":51358942757174,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"6A","offer_id":51358942789942,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"8A","offer_id":51358942822710,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"10A","offer_id":51358942855478,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"12A","offer_id":51358942888246,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"15A","offer_id":51358942921014,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"20A","offer_id":51358942953782,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"30A","offer_id":51358942986550,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"40A","offer_id":51358943019318,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"50A","offer_id":51358943052086,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"60A","offer_id":51358943084854,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"63A","offer_id":51358943117622,"sku":"053-03020","price":35.95,"currency_code":"USD","in_stock":true},{"title":"80A","offer_id":51358943150390,"sku":"053-03020","price":59.75,"currency_code":"USD","in_stock":true},{"title":"100A","offer_id":51358943183158,"sku":"053-03020","price":59.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/150VDCBREAKER.jpg?v=1732917558"},{"product_id":"din-rail-600vdc-fuse-holder","title":"DIN Rail 600VDC Fuse \u0026 Holder","description":"\u003cp\u003e\u003cfont\u003e\u003cstrong\u003eDIN Rail 600VDC Fuses \u0026amp; Holder\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eFuse holder and fuses below fit MidNite MNPV and OutBack FlexPV combiners. Use the fuses and fuse holder below for 600VDC array combiners. Fuses are KLKD for 600 VDC.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cdiv class=\"table\"\u003e\n\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"123\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eAmps\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"123\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eDescription\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\" width=\"123\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-head\"\u003e\u003cstrong\u003e\u003cfont\u003eItem code\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003eUSM1 Fuse Holder - 600V 30A Max - DIN mount\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03040\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-price-col\"\u003e \u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e1\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e1 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03155\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e2\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e2 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03052\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e4\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e4 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03051\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e6\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e6 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03050\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e8\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e8 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03048\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e10\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e10 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03046\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e12\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e12 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03044\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-table-text\"\u003e\u003cfont\u003e15\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e15 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03043\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp align=\"left\" class=\"tables-table-text\"\u003e\u003cfont\u003e20\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e20 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03042\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp align=\"left\" class=\"tables-table-text\"\u003e\u003cfont\u003e30\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-description\"\u003e\u003cfont\u003e30 amp 600 VDC KLKD fuse\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cp class=\"tables-item-code\"\u003e\u003cfont\u003e053-03041\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\n\n\u003cp\u003e \u003cfont\u003e\u003cstrong\u003ePLEASE SPECIFY FUSE REQUIRED BELOW.\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"1A","offer_id":51358942200118,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"2A","offer_id":51358942265654,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"4A","offer_id":51358942298422,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"6A","offer_id":51358942363958,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"8A","offer_id":51358942396726,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"10A","offer_id":51358942429494,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"12A","offer_id":51358942462262,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"15A","offer_id":51358942495030,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"20A","offer_id":51358942527798,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true},{"title":"30A","offer_id":51358942560566,"sku":"053-03040","price":43.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/fuseholder_usm.jpg?v=1732917558"},{"product_id":"trimetric-2030-rv-f-dc-amp-hour-battery-meter-system-monitor","title":"Trimetric 2030-RV-F DC Amp Hour Battery Meter System Monitor","description":"\u003cp\u003e\n\n\t\u003cfont\u003e\u003cstrong\u003eTrimetric 2030 RV Battery Monitor\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont\u003e\u003cstrong\u003ePlease note a shunt is required for use with the trimteric meters.\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"story\"\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cfont\u003eThis updated version of the 2025 amp-hour meter operates on 12, 24 or 48 volts. It reads volts, amps and amp-hours on an LED display. Amp-hours can be displayed in actual amp-hour numbers or as \"% full.\" An LED lights when the battery is charging and flashes when the battery has been fully charged. Another LED flashes when batteries should be recharged, equalized, and during low battery voltage. It also records min and max voltage, days since batteries were last charged, days since equalized, and total lifetime amp-hours withdrawn from the batteries. \u003c\/font\u003e\u003c\/p\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cfont\u003eThe TriMetric can be located hundreds of feet away from batteries using inexpensive 4-conductor twisted-pair meter wire. A shunt is required for operation. Use the 500-amp shunt if you have a 12V inverter larger than 800 watts or a 24V inverter larger than 1600 watts. Use a 1000-amp 100mV shunt for systems with stacked XW inverters or where continuous current is over 300 amps. The 1000A\/100mV shunt has the same resistance as the 500A\/50mV shunt and may be used interchangeably. Order shunt separately. Allows for a maximum battery bank size of 2500 amp-hours. The positive lead to the TriMetric should be fused with a 1-amp fuse. Flush mount or use wiremold box to mount. Made in USA. Dimensions: 4.5\" x 4.75\". 2-year warranty.\u003c\/font\u003e\u003c\/p\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cfont\u003eTM-2025 RV version is a little less wide than the TM-2025A and has surface mounted enclosure. The label colors are more subdued than the TM-2025: beige and black.\u003cbr\u003e\n\n\t\t\u003c\/font\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"table\"\u003e\n\n\t\u003ctable align=\"left\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"WIDTH: 457px; HEIGHT: 297px\"\u003e\n\n\t\t\u003ctbody\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd bgcolor=\"#ffff33\" class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-table-head\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e\u003cstrong\u003eItem code\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-description\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003eTriMetric 2030A amp-hour meter\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-item-code\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e028-00028\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-description\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003eTriMetric 2030-RV amp-hour meter\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-item-code\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e028-00027\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-description\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003eSurface mount box for 2030A\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-item-code\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e028-00026\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-description\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e500A\/50mV shunt\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-item-code\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e028-09253\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-description\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e100A\/100mV shunt\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-item-code\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e028-09245\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\t\u003ctr\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-description\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e1000A\/100mV shunt\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\t\u003ctd\u003e\n\n\t\t\t\t\t\u003cp class=\"tables-item-code\"\u003e\n\n\t\t\t\t\t\t\u003cfont\u003e028-09254\u003c\/font\u003e\u003c\/p\u003e\n\n\t\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003c\/tr\u003e\n\n\t\t\u003c\/tbody\u003e\n\n\t\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cp\u003e\n\n\t \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347869335862,"sku":"028-00027","price":226.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/trimetric2025rv.jpg?v=1732917565"},{"product_id":"midnite-solar-mne-175al-plus-white-aluminum-outback-power-panel-175a","title":"Midnite Solar MNE-175AL-PLUS White Aluminum Outback Power Panel 175A","description":"\u003cdiv class=\"story\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eMidnite E Panel MNE-175AL-PLUS (White Alum Chassis 14.4\" wide)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eOutBack inverters mount on a unique hinged door to keep the footprint of the system as small as possible. They come standard with left-hand hinge, allowing the charge controller to mount on the right. The STS version leaves room for the OutBack AC box with a surge arrestor for grid-tie applications and the \u003cstrong\u003eAL-PLUS version\u003c\/strong\u003e has room to mount an inverter and MX60 on the door.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eMounting brackets are included to aid in one-person installations. Main breaker, inverters cables, a 500-amp\/50mv shunt for battery monitoring systems, 175-amp AC-power distribution block, 50-amp AC-input disconnect for generator or utility, 50-amp AC bypass switch are included and pre-wired. They come with a mounting bracket for an OutBack MX60. Cutouts for mounting up to six additional 13mm-wide DIN rail mount breakers are provided as well as a cutout for a GFCI-style AC outlet.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eSmallest foot-print of any system available for an inverter, charge controler and balance of system components.\u003c\/font\u003e \u003cfont\u003eInverter and charge controller shown not included.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003ctable cellpadding=\"2\" cellspacing=\"2\" style=\"COLOR: #000000\" width=\"100%\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr bgcolor=\"#efefef\"\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cfont color=\"#000000\"\u003e\u003cb\u003e\u003cfont\u003eDescription:\u003c\/font\u003e\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont color=\"#000000\"\u003e\u003cfont\u003eStretched aluminum OB with FM60\/80\/Classic mounting on the door\u003c\/font\u003e\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr bgcolor=\"#efefef\"\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cfont color=\"#000000\"\u003e\u003cb\u003e\u003cfont\u003eWeight\u003c\/font\u003e\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont color=\"#000000\"\u003e\u003cfont\u003e24 Lb\/s\u003c\/font\u003e\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eFor help in choosing the correct Epanel for a particular inverter please view Epanel Matrix Chart below.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347886604598,"sku":"030-05148","price":749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/outBackPlus_Lg_aad10dee-d361-4dc3-a499-ca0afa505230.jpg?v=1732917722"},{"product_id":"midnite-solar-mne-250al-plus-white-aluminum-outback-power-panel-250a","title":"Midnite Solar MNE-250AL-PLUS White Aluminum Outback Power Panel 250A","description":"\u003cdiv class=\"story\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eMidnite E Panel MNE-250AL-PLUS (White Alum Chassis 14.4\" wide)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eOutBack inverters mount on a unique hinged door to keep the footprint of the system as small as possible. They come standard with left-hand hinge, allowing the charge controller to mount on the right. The STS version leaves room for the OutBack AC box with a surge arrestor for grid-tie applications and the \u003cstrong\u003eAL-PLUS version\u003c\/strong\u003e has room to mount an inverter and MX60 on the door.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eMounting brackets are included to aid in one-person installations. Main breaker, inverters cables, a 500-amp\/50mv shunt for battery monitoring systems, 175-amp AC-power distribution block, 50-amp AC-input disconnect for generator or utility, 50-amp AC bypass switch are included and pre-wired. They come with a mounting bracket for an OutBack MX60. Cutouts for mounting up to six additional 13mm-wide DIN rail mount breakers are provided as well as a cutout for a GFCI-style AC outlet.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eSmallest foot-print of any system available for an inverter, charge controler and balance of system components.\u003c\/font\u003e \u003cfont\u003eInverter and charge controller shown not included.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003ctable cellpadding=\"2\" cellspacing=\"2\" style=\"COLOR: #000000\" width=\"100%\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr bgcolor=\"#efefef\"\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cfont color=\"#000000\"\u003e\u003cb\u003e\u003cfont\u003eDescription:\u003c\/font\u003e\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont color=\"#000000\"\u003e\u003cfont\u003eStretched aluminum OB with FM60\/80\/Classic mounting on the door\u003c\/font\u003e\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr bgcolor=\"#efefef\"\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cfont color=\"#000000\"\u003e\u003cb\u003e\u003cfont\u003eWeight\u003c\/font\u003e\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont color=\"#000000\"\u003e\u003cfont\u003e24 Lb\/s\u003c\/font\u003e\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eFor help in choosing the correct Epanel for a particular inverter please view Epanel Matrix Chart below.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347886637366,"sku":"030-05149","price":749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/outBackPlus_Lg_fcbdb380-39dc-44c5-9b1c-24bf8b79666f.jpg?v=1732917722"},{"product_id":"midnite-solar-mne250stm-l-grey-steel-magnum-power-panel-250a-inverter-breaker","title":"Midnite Solar MNE250STM-L Grey Steel Magnum Power Panel 250A INVERTER BREAKER","description":"\u003cp\u003e\u003cfont\u003e\u003cstrong\u003eMidnite 250STM-L (Gray Steel chassis with 250amp inverter breaker)\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003eMagnum inverters mount on a unique hinged door to keep the footprint of the system as small as possible. Mounting brackets are included to aid in one-person installations. They come with a main breaker, 2\/0 inverters cables, a 500-amp\/50mv shunt for battery monitoring systems, an AC input and bypass, PV input busbars, DIN rails, 3-panel mount breaker knockouts, ground bus, remote display mounting brackets, charge controller bracket, wall mount bracket and lots of hardware. 120\/240 models are for Magnum MS-AE inverters.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable style=\"COLOR: #000000\" cellspacing=\"2\" cellpadding=\"2\" width=\"100%\"\u003e\n\n    \u003ctbody\u003e\n\n        \u003ctr bgcolor=\"#efefef\"\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eDescription:\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eGray steel with 250a breaker for MS4024\/ MS2812\/MS2012\/MS4124E \u0026amp; RD series.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr bgcolor=\"#efefef\"\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eWeight\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e39 Lb\/s\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347886670134,"sku":"030-05164","price":749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/mne250stm-L.jpg?v=1732917723"},{"product_id":"midnite-solar-mne175stm-l-grey-steel-magnum-power-panel-175a-inverter-breaker","title":"Midnite Solar MNE175STM-L Grey Steel Magnum Power Panel 175A INVERTER BREAKER","description":"\u003cp\u003e\u003cfont\u003e\u003cstrong\u003eMidnite 175STM-L (Gray Steel chassis with 175amp inverter breaker)\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003eMagnum inverters mount on a unique hinged door to keep the footprint of the system as small as possible. Mounting brackets are included to aid in one-person installations. They come with a main breaker, 2\/0 inverters cables, a 500-amp\/50mv shunt for battery monitoring systems, an AC input and bypass, PV input busbars, DIN rails, 3-panel mount breaker knockouts, ground bus, remote display mounting brackets, charge controller bracket, wall mount bracket and lots of hardware. 120\/240 models are for Magnum MS-AE inverters.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\u003c\/p\u003e\u003ctable style=\"COLOR: #000000\" cellspacing=\"2\" cellpadding=\"2\" width=\"100%\"\u003e\n\n    \u003ctbody\u003e\n\n        \u003ctr bgcolor=\"#efefef\"\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eDescription:\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eGray steel with 175a\/125VDC inverter breaker for RD1824, RD2824, RD2624E and MS2712E\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr bgcolor=\"#efefef\"\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eWeight\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e39 Lb\/s\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n\n\u003c\/table\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347886735670,"sku":"030-05160","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/mne250stm-L_ef764b3c-24fe-4819-a582-8525729cba8a.jpg?v=1732917723"},{"product_id":"midnite-solar-mne175stm-240-white-steel-magnum-power-panel-175a-inverter-breaker","title":"Midnite Solar MNE175STM-240 White Steel Magnum Power Panel 175A INVERTER BREAKER","description":"\u003cp\u003e\u003cfont\u003e\u003cstrong\u003eMidnite 175STM-240 (White steel chassis with 175amp inverter breaker for 1120\/240Vac)\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eMagnum inverters mount on a unique hinged door to keep the footprint of the system as small as possible. Mounting brackets are included to aid in one-person installations. They come with a main breaker, 2\/0 inverters cables, a 500-amp\/50mv shunt for battery monitoring systems, an AC input and bypass, PV input busbars, DIN rails, 3-panel mount breaker knockouts, ground bus, remote display mounting brackets, charge controller bracket, wall mount bracket and lots of hardware. 120\/240 models are for Magnum MS-AE inverters.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cspan style=\"COLOR: red\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eThe AE series comes with all the regular E-Panel features plus terminal bus bars for 120\/240VAC input and output.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\n\n\u003ctable cellpadding=\"2\" cellspacing=\"2\" style=\"COLOR: #000000\" width=\"100%\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr bgcolor=\"#efefef\"\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eDescription:\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont\u003eWhite steel for 120\/240VAC in \u0026amp; out for MS4448-AE \u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr bgcolor=\"#efefef\"\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eWeight\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont\u003e42 Lb\/s\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887030582,"sku":"030-05167","price":795.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/magnumAE_Lg.jpg?v=1732917727"},{"product_id":"midnite-solar-mne250stm-240-white-steel-magnum-power-panel-250a-inverter-breaker","title":"Midnite Solar MNE250STM-240 White Steel Magnum Power Panel 250A INVERTER BREAKER","description":"\u003cp\u003e\u003cfont\u003e\u003cstrong\u003eMidnite 250STM-240 (White steel chassis with 250amp inverter breaker for 1120\/240Vac)\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eMagnum inverters mount on a unique hinged door to keep the footprint of the system as small as possible. Mounting brackets are included to aid in one-person installations. They come with a main breaker, 2\/0 inverters cables, a 500-amp\/50mv shunt for battery monitoring systems, an AC input and bypass, PV input busbars, DIN rails, 3-panel mount breaker knockouts, ground bus, remote display mounting brackets, charge controller bracket, wall mount bracket and lots of hardware. 120\/240 models are for Magnum MS-AE inverters.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cspan style=\"COLOR: red\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eThe AE series comes with all the regular E-Panel features plus terminal bus bars for 120\/240VAC input and output.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\n\n\u003ctable cellpadding=\"2\" cellspacing=\"2\" style=\"COLOR: #000000\" width=\"100%\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr bgcolor=\"#efefef\"\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eDescription:\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont\u003eWhite steel for 120\/240VAC in \u0026amp; out for MS4024-AE \u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr bgcolor=\"#efefef\"\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eWeight\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont\u003e42 Lb\/s\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887063350,"sku":"030-05169","price":795.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/magnumAE_Lg_39c15338-4483-416a-b559-0df788a00846.jpg?v=1732917727"},{"product_id":"midnite-solar-mne250xw-power-panel-to-mount-under-xw-inverter-250amp-inverter-breaker","title":"Midnite Solar MNE250XW Power Panel to mount under XW Inverter 250amp Inverter Breaker","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMidnite MNE250XW (Epanel to mount under one XW inverter)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe XW inverter is mounted directly above the E-Panel. It comes with a 250-amp inverter battery breaker, AC inputs for generator and utility, knockouts for up to 7 DIN rail mount breakers and 6 panel mount breakers and a 500-amp shunt. Massive tin-plated copper bus bars connect to the XW’s battery terminals. There are bus bars for AC inputs, AC output, neutral, ground, PV + in, PV- in, Bat +, Bat-, covered by a metal dead-front behind the reversible door. Charge controllers mount to either side or both sides at once for dual controllers. The AC bypass can be configured as input and output on\/off as well as AC bypass. The XW MPPT controller requires no mounting bracket. MX60, MF80 and Classic require right or left E-Panel charge controller mounting brackets. A right-hand bracket is included. The color-matched enclosure is 16\" wide, 18\" tall, 8\" deep and weighs 42 pounds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e inverter battery breaker, 2 separate 60 amp AC inputs for generator and utility, 60 amp AC bypass switch, knockouts for up to seven din rail mount DC, DCGFP63 or AC breakers and 12 panel mount or DC-GFP80 breakers. Massive tin plated copper bus bars directly connect to the XW’s battery terminals, bus bars for AC inputs, AC output, neutral, ground, PV + in, PV- in, Bat +, Bat-, 500 amp shunt, metal dead front behind the reversible door, Charge controllers mount to either side or both sides at once for dual controllers. AC bypass can be configured as input \u0026amp; output on\/off as well as AC bypass. The XW MPPT controller requires no mounting bracket. FM60, FM80 and Classic require Right or Left E-Panel charge control mounting brackets. Right hand bracket furnished standard. \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"color: #000000;\" cellspacing=\"2\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cspan\u003eDescription:\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE-Panel for a single Xantrex XW inverter\/charger The XW inverter is mounted directly above the E-Panel for a 16” assembly. Save $600 over the price of the Xantrex distribution panel and get additional features.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42 Lb\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887292726,"sku":"030-05181","price":909.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/MS-E-Panel-MNE250XW-2.jpg?v=1750926666"},{"product_id":"midnite-solar-mne175dr-tr-l-gray-steel-power-panel-for-xantrex-dr-tr-series-175-amp","title":"Midnite Solar MNE175DR\/TR-L Gray Steel Power Panel for Xantrex DR\/TR series  175 amp","description":"\u003cp\u003e\u003cstrong\u003e\u003cfont\u003eMidnite MNE175DR\/TR-L  (Epanel to mount one DR\/TR inverter)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003eThis unit is also designed for the Trace DR series and works for the replacement “TR” inverter from Xantrex and the full length Samlex inverters. It comes with all the normal E-Panel features such as inverter cables, PV+ busbar, battery+ busbar, 50 amp AC input\/output bypass, 50 amp AC input disconnect, 125VDC inverter battery breaker, AC busbars, covers for DC and AC end, wall mounting brackets, charge control bracket and hardware. AC breakers are rated at 277VAC. \u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003ctable style=\"COLOR: #000000\" cellspacing=\"2\" cellpadding=\"2\" width=\"100%\"\u003e\n\n    \u003ctbody\u003e\n\n        \u003ctr bgcolor=\"#efefef\"\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eDescription:\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eWorks with all DR, TR and full length Samlex S series\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr bgcolor=\"#efefef\"\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cfont\u003eWeight\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e30 Lb\/s\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr bgcolor=\"#efefef\"\u003e\n\n            \u003ctd colspan=\"2\"\u003e\u003cfont\u003eAC and DC covers provided.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cfont\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887325494,"sku":"030-05186","price":472.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/PS-XTX-MNE250DR-030-05187.jpg?v=1732917730"},{"product_id":"midnite-solar-mne175xw-power-panel-to-mount-under-xw-inverter-175amp-inverter-breaker","title":"Midnite Solar MNE175XW Power Panel to mount under XW Inverter 175amp Inverter Breaker","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMidnite MNE175XW (Epanel to mount under one XW inverter)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe XW inverter is mounted directly above the E-Panel. It comes with a 175-amp inverter battery breaker, AC inputs for generator and utility, knockouts for up to 7 DIN rail mount breakers and 6 panel mount breakers and a 500-amp shunt. Massive tin-plated copper bus bars connect to the XW’s battery terminals. There are bus bars for AC inputs, AC output, neutral, ground, PV + in, PV- in, Bat +, Bat-, covered by a metal dead-front behind the reversible door. Charge controllers mount to either side or both sides at once for dual controllers. The AC bypass can be configured as input and output on\/off as well as AC bypass. The XW MPPT controller requires no mounting bracket. MX60, MF80 and Classic require right or left E-Panel charge controller mounting brackets. A right-hand bracket is included. The color-matched enclosure is 16\" wide, 18\" tall, 8\" deep and weighs 42 pounds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e inverter battery breaker, 2 separate 60 amp AC inputs for generator and utility, 60 amp AC bypass switch, knockouts for up to seven din rail mount DC, DCGFP63 or AC breakers and 12 panel mount or DC-GFP80 breakers. Massive tin plated copper bus bars directly connect to the XW’s battery terminals, bus bars for AC inputs, AC output, neutral, ground, PV + in, PV- in, Bat +, Bat-, 500 amp shunt, metal dead front behind the reversible door, Charge controllers mount to either side or both sides at once for dual controllers. AC bypass can be configured as input \u0026amp; output on\/off as well as AC bypass. The XW MPPT controller requires no mounting bracket. FM60, FM80 and Classic require Right or Left E-Panel charge control mounting brackets. Right hand bracket furnished standard. \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"2\" cellspacing=\"2\" style=\"color: #000000;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cspan\u003eDescription:\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE-Panel for a single Xantrex XW inverter\/charger The XW inverter is mounted directly above the E-Panel for a 16” assembly.Save $600 over the price of the Xantrex distribution panel and get additional features.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42 Lb\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887358262,"sku":"030-05182","price":959.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/XWepanel_af72f149-e9bc-497c-9df4-9f4315e0b046.jpg?v=1732917731"},{"product_id":"midnite-solar-mne250dr-tr-l-gray-steel-power-panel-for-xantrex-dr-tr-series-250-amp","title":"Midnite Solar MNE250DR\/TR-L Gray Steel Power Panel for Xantrex DR\/TR series  250 amp","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMidnite MNE250DR\/TR-L (Epanel to mount one DR\/TR inverter)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis unit is also designed for the Trace DR series and works for the replacement “TR” inverter from Xantrex and the full length Samlex inverters. It comes with all the normal E-Panel features such as inverter cables, PV+ busbar, battery+ busbar, 50 amp AC input\/output bypass, 50 amp AC input disconnect, 125VDC inverter battery breaker, AC busbars, covers for DC and AC end, wall mounting brackets, charge control bracket and hardware. AC breakers are rated at 277VAC. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" cellpadding=\"2\" cellspacing=\"2\" style=\"color: #000000;\"\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cspan\u003eDescription:\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWorks with all DR, TR and full length Samlex S series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd valign=\"top\"\u003e\u003cb\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 Lb\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eAC and DC covers provided.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887522102,"sku":"030-05187","price":495.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/MS-E-Panel-MNE250DR-TR-L-3T.jpg?v=1750926338"},{"product_id":"midnite-solar-mne175lt-gray-steel-power-panel-w-175amp-inverter-breaker","title":"Midnite Solar MNE175LT Gray Steel Power Panel w\/ 175amp Inverter Breaker","description":"\u003cp\u003e\u003cstrong\u003eMidnite MNE175LT\n\n\u003cp class=\"tables-description\"\u003eGray steel chassis with 175-amp inverter breaker (Lite)\u003c\/p\u003e\n\n\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe E-Panel Lites come with a left-hand door, inverter breaker, pre-wired AC input and bypass, 500-amp\/50mV shunt, AC terminal blocks, DIN rails, wall mounting brackets, instructions and lots of hardware. \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887882550,"sku":"030-05109","price":484.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Stretched_OB_Lg_1fae91e8-0c6c-4fd1-a8b1-8da5a1b63670.jpg?v=1732917738"},{"product_id":"midnite-solar-mne250lt-gray-steel-power-panel-w-250amp-inverter-breaker","title":"Midnite Solar MNE250LT Gray Steel Power Panel w\/ 250amp Inverter Breaker","description":"\u003cp\u003e\u003cstrong\u003eMidnite MNE250LT\n\n\u003cp class=\"tables-description\"\u003eGray steel chassis with 250-amp inverter breaker (Lite)\u003c\/p\u003e\n\n\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe E-Panel Lites come with a left-hand door, inverter breaker, pre-wired AC input and bypass, 500-amp\/50mV shunt, AC terminal blocks, DIN rails, wall mounting brackets, instructions and lots of hardware. \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887915318,"sku":"030-05113","price":484.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Stretched_OB_Lg_315b0be0-7456-4b79-8443-2b54a333f05a.jpg?v=1732917738"},{"product_id":"midnite-solar-mne250alt-white-alum-power-panel-w-250amp-inverter-breaker","title":"Midnite Solar MNE250ALT White Alum Power Panel w\/ 250amp Inverter Breaker","description":"\u003cp\u003e\u003cstrong\u003eMidnite MNE250LT\n\n\u003cp class=\"tables-description\"\u003eWhite alum chassis with 250-amp inverter breaker (Lite)\u003c\/p\u003e\n\n\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe E-Panel Lites come with a left-hand door, inverter breaker, pre-wired AC input and bypass, 500-amp\/50mV shunt, AC terminal blocks, DIN rails, wall mounting brackets, instructions and lots of hardware. \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887948086,"sku":"030-05103","price":528.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Stretched_OB_Lg_393dae0f-cc6c-4bf3-b521-9d08122faf09.jpg?v=1732917738"},{"product_id":"midnite-solar-mne175alt-white-alum-power-panel-w-175amp-inverter-breaker","title":"Midnite Solar MNE175ALT White Alum Power Panel w\/ 175amp Inverter Breaker","description":"\u003cp\u003e\u003cstrong\u003eMidnite MNE175ALT\n\n\u003cp class=\"tables-description\"\u003eWhite alum chassis with 175-amp inverter breaker (Lite)\u003c\/p\u003e\n\n\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe E-Panel Lites come with a left-hand door, inverter breaker, pre-wired AC input and bypass, 500-amp\/50mV shunt, AC terminal blocks, DIN rails, wall mounting brackets, instructions and lots of hardware. \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347887980854,"sku":"030-05102","price":528.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Stretched_OB_Lg_9e120303-7d7c-4c35-b385-ce009904c175.jpg?v=1732917739"},{"product_id":"midnite-mne125alt","title":"Midnite MNE125ALT","description":"\u003cp\u003e\u003cstrong\u003eMidnite MNE125ALT\n\n\u003cp class=\"tables-description\"\u003eWhite alum chassis with 125-amp inverter breaker (Lite)\u003c\/p\u003e\n\n\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe E-Panel Lites come with a left-hand door, inverter breaker, pre-wired AC input and bypass, 500-amp\/50mV shunt, AC terminal blocks, DIN rails, wall mounting brackets, instructions and lots of hardware. \u003c\/p\u003e","brand":"Midnite Solar Inc","offers":[{"title":"Default Title","offer_id":51347888079158,"sku":"030-05101","price":484.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Stretched_OB_Lg_83ce50cd-d004-423f-96e0-92b45316361b.jpg?v=1732917741"},{"product_id":"flexcharge-dc-ac-timer","title":"Flexcharge DC\/AC Timer","description":"\u003cp\u003e\n\n\t\u003cfont\u003e\u003cstrong\u003eFlexcharge DC\/AC Timer\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"story\"\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cfont\u003eThe Flexcharge digital timer is a 7-day, 8-event digital clock based programmable load controller. Eight ON and eight OFF events can be programmed independently, each with its own unique timing pattern. For example: use one ON event to have a light come on at 7 pm every day then use seven OFF events to turn the light off at a different time each day. The replaceable internal battery maintains the clock and programmed memory in the event of a system power failure (for up to 3 months). Consumes less then 3mA in standby mode. Internal DPST (double-pole-single-throw) relay switch can turn one load on at the same time that it turns another load off. Timer switch can handle up to 8 amps of inductive load or up to 16 amps of resistive load, at 6 to 36VDC or 120VAC. Timer requires 12V DC or AC to operate. Reverse polarity protected. Manual override allows the user to turn the load ON or OFF as desired. Easy to use terminal block for wiring. Dry contacts.\u003c\/font\u003e\u003c\/p\u003e\n\n\t\u003cp\u003e\n\n\t\t\u003cfont\u003e1-year warranty. Dimensions: 3.9\"W x 3.8\"H x 2\"D\u003c\/font\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Flexcharge","offers":[{"title":"Default Title","offer_id":51347898990902,"sku":"054-07120","price":96.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/flexcharge-8-event-programmable-12-volt-timer-1000x1000.jpg?v=1750928748"},{"product_id":"flexcharge-nightwatchman-12v-photoswitch","title":"Flexcharge Nightwatchman 12v Photoswitch","description":"\u003cdiv class=\"story\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFlexcharge Night Watchman 12v Dusk to Dawn Photoswitch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Flexcharge Night Watchman dusk-to-dawn controller is designed to be mounted outside in a marine salt air environment. It is completely waterproof, and very small (1\" x 1\" x 1\") for mounting in an inconspicuous location.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause power consumption is always a concern on battery powered systems (sail boats, PV systems, etc.) the Night Watchman is designed to use an extremely small amount of power in standby mode (only 0.00015A or 0.15mA), yet it is capable of supplying up to 10A of load current.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Night Watchman will turn 12V incandescent or fluorescent lights ON in the evening within a half hour of sunset, and OFF in the morning within a half hour of sun rise.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Night Watchman’s circuitry is designed to prevent flickering therefore it can be used to control 12V fluorescent lamps. 1-year warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Flexcharge","offers":[{"title":"Default Title","offer_id":51347899023670,"sku":"054-07215","price":59.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Screenshot_2024-04-12_173807__51052.png?v=1750929042"},{"product_id":"rab-12v-motion-sensor-switch","title":"RAB 12v Motion Sensor Switch","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRAB 12v Motion Sensor Switch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRAB motion and heat sensing switch is 12-volt DC powered so it works full time even if your inverter is in standby or off. Turns lights on at approach, and holds for adjustable time, 5 seconds to 20 minutes after motion stops. Sensitivity distance is adjustable, up to about 50 feet out, farther in colder weather. Connect directly to any 12-volt light, or use a 12-volt relay to switch 120-volt lights. Set for night only operation, or use as security alarm, by setting for day\/night operation. Switches - amp DC, uses only 7 milliamps at idle, 40 milliamps when activating. Switch uses only 7 milliamps at idle.\u003cbr\u003e1-year warranty.\u003c\/span\u003e\u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347899121974,"sku":"054-07237","price":156.56,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/StealthMotionsensor.jpg?v=1732917854"},{"product_id":"shunt-mkb-500-50-500amp-50mv-shunt","title":"SHUNT MKB-500-50 500amp, 50mV Shunt","description":"\u003cp\u003e\u003cfont\u003e\u003cstrong\u003eSHUNT MKB-500-50 500amp, 50mV Shunt\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003eShunt for use in DC monitor systems. Use the 500amp shunt if you have a 12v inverter larger than 800 watts or a 24v inverter larger than 1600w or if you are using the Flexnet Dc monitor. Use a 1000 amp shunt if you have stacked XW inverters or where continuous current is over 300amps.\u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347901415734,"sku":"028-09253","price":59.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/shunt.jpg?v=1732917873"},{"product_id":"shunt-mkb-1000-100-1000amp-100mv-shunt","title":"SHUNT MKB-1000-100 1000amp, 100mV Shunt","description":"\u003cp\u003e\u003cfont\u003e\u003cstrong\u003eSHUNT MKB-1000-100 1000amp, 100mV Shunt\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003eShunt for use in DC monitor systems. Use the 500amp shunt if you have a 12v inverter larger than 800 watts or a 24v inverter larger than 1600w or if you are using the Flexnet Dc monitor. Use a 1000 amp shunt if you have stacked XW inverters or where continuous current is over 300amps.\u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347901481270,"sku":"028-09254","price":97.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/shunt_9cc71ba8-f507-46db-91fd-8e32bc05ac09.jpg?v=1732917874"},{"product_id":"la302dc-delta-lightning-arrestor-to-0-300vdc","title":"LA302DC Delta Lightning Arrestor to 0-300VDC","description":"\u003cdiv class=\"story\"\u003e\n\n\u003cp class=\"main-text\"\u003e\u003cstrong\u003e\u003cfont\u003eLA302DC Delta Lightning Arrestor Surge Protection to 0-300VDC\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eDelta lightning arrestors have a maximum current rating of 60,000 amps and 2,000 joules per line. Response time is 25 ns to clamp 50,000 amps. Mounts easily in a 1\/2\" knockout.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eInstall the DC version for surge protection on wires coming from a PV array, DC wind generator or DC hydroelectric turbine. Use the 600VDC unit for high-voltage grid-tie PV arrays. Lightning protection can be installed in a combiner box, DC load center or grid-tie inverter.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eThe AC versions can be mounted in your AC load center to protect 120\/240 VAC equipment and on AC wiring running outside of the building, to generators, pumps or outbuildings. All units are waterproof.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Delta Lightning Arrestors","offers":[{"title":"Default Title","offer_id":51347902857526,"sku":"053-04115","price":69.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/delta_lightning_arrestor_302-dc-pic.png?v=1779390942"},{"product_id":"citel-ds220s-24dc-24vdc-off-grid-surge-arrestor","title":"Citel DS220S-24DC 24VDC Off Grid Surge Arrestor","description":"\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003e\u003cstrong\u003eCitel DS220S-24DC 24VDC Off Grid Surge Arrestor\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003eThe Citel DS220DC series is designed to protect 12V, 24V, 48V and 150V DC power lines for an off-grid PV system. The surge protectors protect the charge controller and other system electronics. DS220DC automatically reset after each lightning surge or electrical transient. These surge arrestors clamp at much lower voltage than Delta surge arrestors at left so they offer much better protection for charge controllers and inverters in low-voltage DC systems.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003eCitel PV surge protectors are DIN mount and are ideal for placement inside combiner boxes.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\n\n\t\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\n\n\t\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t \u003c\/p\u003e\n\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" width=\"601\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd width=\"181\"\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"15\"\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"403\"\u003e\n\n\t\t\t\t\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\n\n\t\t\t\t\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e\n\n\t \u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\n\tSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003cstrong\u003e \u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\t\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\n\tAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903185206,"sku":"053-04203","price":90.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/DS210-12DC.jpg?v=1732917895"},{"product_id":"citel-ds220s-12dc-12vdc-off-grid-surge-arrestor","title":"Citel DS220S-12DC 12VDC Off Grid Surge Arrestor","description":"\u003cp class=\"main-text\"\u003e\u003cfont\u003e\u003cstrong\u003eCitel DS220S-12DC 12VDC Off Grid Surge Arrestor ( previous # DS210-12DC)\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eThe Citel DS220SDC series is designed to protect 12V, 24V, 48V and 150V DC power lines for an off-grid PV system. The surge protectors protect the charge controller and other system electronics. DS220SDC automatically reset after each lightning surge or electrical transient. These surge arrestors clamp at much lower voltage than Delta surge arrestors at left so they offer much better protection for charge controllers and inverters in low-voltage DC systems.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eCitel PV surge protectors are DIN mount and are ideal for placement inside combiner boxes.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp class=\"style63\"\u003e\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\n\n\u003cp class=\"style63\"\u003e\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\n\u003cp class=\"main-text\"\u003e \u003c\/p\u003e\n\n\n\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" width=\"601\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd width=\"181\"\u003e\n\n\t\t\t\u003cdiv align=\"right\"\u003e\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"15\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"403\"\u003e\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cdiv align=\"right\"\u003e\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cdiv align=\"right\"\u003e\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\u003cdiv align=\"right\"\u003e\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\n\n\u003cp\u003e \u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\nSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cstrong\u003e\u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\nAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903217974,"sku":"053-04201","price":90.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/DS210-12DC_3fc576de-8a0c-430f-bac9-dff3652afc0f.jpg?v=1732917895"},{"product_id":"citel-ds230-48dc-48vdc-off-grid-surge-arrestor","title":"Citel DS230-48DC 48VDC Off Grid Surge Arrestor","description":"\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003e\u003cstrong\u003eCitel DS230-48DC 48VDC Off Grid Surge Arrestor\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003eThe Citel DS230DC series is designed to protect 12V, 24V, 48V and 150V DC power lines for an off-grid PV system. The surge protectors protect the charge controller and other system electronics. DS230DC automatically reset after each lightning surge or electrical transient. These surge arrestors clamp at much lower voltage than Delta surge arrestors at left so they offer much better protection for charge controllers and inverters in low-voltage DC systems.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003eCitel PV surge protectors are DIN mount and are ideal for placement inside combiner boxes.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\n\n\t\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\n\n\t\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t \u003c\/p\u003e\n\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" width=\"601\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd width=\"181\"\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"15\"\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"403\"\u003e\n\n\t\t\t\t\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\n\n\t\t\t\t\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e\n\n\t \u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\n\tSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003cstrong\u003e \u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\t\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\n\tAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903283510,"sku":"053-04205","price":90.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/DS210-12DC_68ef09ca-e71d-4c09-9062-b560f01475dd.jpg?v=1732917898"},{"product_id":"citel-ds240-95dc-95vdc-off-grid-surge-arrestor","title":"Citel DS240-95DC 95VDC Off Grid Surge Arrestor","description":"\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003e\u003cstrong\u003eCitel DS240-95DC 95VDC Off Grid Surge Arrestor\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003eThe Citel DS240DC series is designed to protect 12V, 24V, 48V and 150V DC power lines for an off-grid PV system. The surge protectors protect the charge controller and other system electronics. DS240DC automatically reset after each lightning surge or electrical transient. These surge arrestors clamp at much lower voltage than Delta surge arrestors at left so they offer much better protection for charge controllers and inverters in low-voltage DC systems.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003eCitel PV surge protectors are DIN mount and are ideal for placement inside combiner boxes.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\n\n\t\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\n\n\t\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t \u003c\/p\u003e\n\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" width=\"601\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd width=\"181\"\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"15\"\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"403\"\u003e\n\n\t\t\t\t\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\n\n\t\t\t\t\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e\n\n\t \u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\n\tSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003cstrong\u003e \u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\t\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\n\tAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903381814,"sku":"053-04207","price":90.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/DS210-12DC_d2929672-7f0e-4c51-83fe-e2ab453154f5.jpg?v=1732917898"},{"product_id":"citel-ds230-150dc-150vdc-off-grid-surge-arrestor","title":"Citel DS230-150DC 150VDC Off Grid Surge Arrestor","description":"\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003e\u003cstrong\u003eCitel DS230-150DC 150VDC Off Grid Surge Arrestor\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003eThe Citel DS230DC series is designed to protect 12V, 24V, 48V and 150V DC power lines for an off-grid PV system. The surge protectors protect the charge controller and other system electronics. DS210DC automatically reset after each lightning surge or electrical transient. These surge arrestors clamp at much lower voltage than Delta surge arrestors at left so they offer much better protection for charge controllers and inverters in low-voltage DC systems.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t\u003cfont\u003eCitel PV surge protectors are DIN mount and are ideal for placement inside combiner boxes.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\n\n\t\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\n\n\t\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\t \u003c\/p\u003e\n\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" width=\"601\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd width=\"181\"\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"15\"\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd width=\"403\"\u003e\n\n\t\t\t\t\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003e\n\n\t\t\t\t\u003cdiv align=\"right\"\u003e\n\n\t\t\t\t\t\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\n\u003c\/div\u003e\n\n\t\t\t\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\n\n\t\t\t\t\u003cfont\u003e \u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\t\u003ctd valign=\"top\"\u003e\n\n\t\t\t\t\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\n\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e\n\n\t \u003c\/p\u003e\n\n\u003cp\u003e\n\n\t\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\n\tSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003cstrong\u003e \u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\t\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\t\u003cbr\u003e\n\n\t\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\n\tAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903512886,"sku":"053-04209","price":131.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/DS210-12DC_86855d5e-9778-42b9-96cf-220b264acc06.jpg?v=1732917898"},{"product_id":"citel-ds50pv-600-600vdc-grid-tie-surge-arrestor","title":"Citel DS50PV-600 600VDC Grid Tie Surge Arrestor","description":"\u003cp class=\"main-text\"\u003e\u003cfont\u003e\u003cstrong\u003eCitel DS50PV-600 600VDC Grid Tie Surge Arrestor\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eThe DS50PV is designed to protect the solar array at the solar PV array combiner box for a utility-interactive PV system. The DS50PV is designed to withstand 40kA (8\/20us) induced transient surges and is designed with replaceable modules. Use the DS50PV-600 for systems with inverters that have an upper limit of up to 600 volts. \u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eCitel PV surge protectors are DIN mount and are ideal for placement inside combiner boxes.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e \u003c\/p\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" width=\"601\"\u003e\n\n    \u003ctbody\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd width=\"181\"\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd width=\"15\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd width=\"403\"\u003e\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\nSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cstrong\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\nAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903545654,"sku":"053-04218","price":141.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/DS50PV.jpg?v=1732917898"},{"product_id":"citel-ds60pv-500-500vdc-grid-tie-surge-arrestor","title":"Citel DS60PV-500 500VDC Grid Tie Surge Arrestor","description":"\u003cfont\u003e\u003cstrong\u003e\n\n\u003cdiv class=\"main-text\"\u003e\n\u003cfont\u003e\u003cstrong\u003eCitel DS60PV-500 500VDC Grid Tie Surge Arrestor\u003c\/strong\u003e\u003c\/font\u003e\u003cfont\u003eDS60PV are Type 1 heavy duty surge protectors, recommended when a direct lightning strike is possible on the installation. They are available in 500- and 1000-VDC operating voltages. The use of Type 1 surge protector is recommended at both ends of the DC power supply line (solar array side and inverter\/converter side). The DS60PV is made with a monobloc enclosure and mounts on DIN rail. \u003c\/font\u003e\n\u003c\/div\u003e\n\n\u003c\/strong\u003e\u003c\/font\u003e\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eCitel PV surge protectors are DIN mount and are ideal for placement inside combiner boxes.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e \u003c\/p\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" width=\"601\"\u003e\n\n    \u003ctbody\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd width=\"181\"\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd width=\"15\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd width=\"403\"\u003e\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\nSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cstrong\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\nAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903709494,"sku":"053-04224","price":185.22,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/DS60PV.jpg?v=1732917901"},{"product_id":"citel-ds60pv-1000-1000vdc-grid-tie-surge-arrestor","title":"Citel DS60PV-1000 1000VDC Grid Tie Surge Arrestor","description":"\u003cfont\u003e\n\n\u003cdiv class=\"main-text\"\u003e\u003cfont\u003e\u003cstrong\u003eCitel DS60PV-1000 1000VDC Grid Tie Surge Arrestor\u003c\/strong\u003e\u003c\/font\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"main-text\"\u003e \u003c\/div\u003e\n\n\u003cdiv class=\"main-text\"\u003e\u003cfont\u003eDS60PV are Type 1 heavy duty surge protectors, recommended when a direct lightning strike is possible on the installation. They are available in 500- and 1000-VDC operating voltages. The use of Type 1 surge protector is recommended at both ends of the DC power supply line (solar array side and inverter\/converter side). The DS60PV is made with a monobloc enclosure and mounts on DIN rail. \u003c\/font\u003e\u003c\/div\u003e\n\n\u003c\/font\u003e\n\n\u003cp class=\"main-text\"\u003e\u003cfont\u003eCitel PV surge protectors are DIN mount and are ideal for placement inside combiner boxes.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e \u003c\/p\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" width=\"601\"\u003e\n\n    \u003ctbody\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd width=\"181\"\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd width=\"15\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd width=\"403\"\u003e\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\nSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cstrong\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\nAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903742262,"sku":"053-04226","price":307.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/DS60PV_ebabf7f0-dc17-4422-9f57-5a8a845b61ef.jpg?v=1732917902"},{"product_id":"citel-ds240-120-120vac-grid-tie-surge-arrestor","title":"Citel DS240-120 120VAC Grid Tie Surge Arrestor","description":"\u003cfont\u003e\n\n\u003cdiv class=\"main-text\"\u003e\u003cfont\u003e\u003cstrong\u003eCitel DS240-120 120VAC Grid Tie Surge Arrestor\u003c\/strong\u003e\u003c\/font\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"main-text\"\u003e \u003c\/div\u003e\n\n\u003cdiv class=\"main-text\"\u003e\u003cfont\u003e\n\n\u003cp class=\"main-text\"\u003eThe DS240 is DIN rail compatible and is built with a plug-in module and a fixed base, which enables easy and fast maintenance.\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e120VAC only. Two units cannot be used to provide protection for a 240V split-phase system.\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003eCitel’s DS240 surge protectors are used mainly for distribution panels of single-phase and three-phase networks. They provide common-mode protection (between the active conductors and ground) and are available with an option remote alarm.\u003cbr\u003e\n\n\u003cbr\u003e\n\nThe DS240 is built with a plug-in module and a fixed base, which allows for easy access to protection modules.\u003c\/p\u003e\n\n\u003c\/font\u003e\u003c\/div\u003e\n\n\u003c\/font\u003e\n\n\u003cp\u003e\u003cfont color=\"#363636\"\u003e\u003cspan class=\"style51 style58\"\u003e\u003cstrong\u003e\u003cfont color=\"#000000\"\u003eDC Power Surge Protection Overview\u003c\/font\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cfont\u003eSolar Photovoltaic (PV) Systems are very demanding and cost intensive projects. They often require the Solar PV System to be operational for several decades before it can yield the desired return on investment.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\u003cfont\u003eMany manufacturers will guarantee a system life of greater than 20 years while the inverter is generally guaranteed for only 5-10 years. All costs and return on investments are calculated based on these time periods. However, many PV systems are not reaching maturity due to the exposed nature of these applications and its interconnection back to the AC utility grid. The solar PV arrays, with its metallic frame and mounted in the open or on roof tops, act as a very good lightning rod. For this reason, it is prudent to invest in surge protection to eliminate these potential threats and thus maximize the systems life expectancy. The cost for a comprehensive surge protection system is less than 1% of the total system expenditure.\u003c\/font\u003e\u003c\/p\u003e\n\n\u003cp class=\"style63\"\u003e\u003cstrong\u003e\u003cfont\u003eTo analyze the full threat level of the installation, we must make a risk assessment.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e \u003c\/p\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" width=\"601\"\u003e\n\n    \u003ctbody\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd width=\"181\"\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eOperational Downtime Risk – \u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd width=\"15\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd width=\"403\"\u003e\u003cfont\u003eAreas with severe lightning and unstable utility power are more vulnerable.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003ePower Interconnection Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eThe greater the surface area of the solar PV array, the more exposure to direct and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eApplication Surface Area Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd\u003e\u003cfont\u003eThe AC utility grid is a likely source of switching transients and\/or induced lightning surges. \u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n\n            \u003ctd\u003e\n\n            \u003cdiv align=\"right\"\u003e\u003cfont\u003eGeographic Risk –\u003c\/font\u003e\u003c\/div\u003e\n\n            \u003c\/td\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cfont\u003e \u003c\/font\u003e\u003c\/td\u003e\n\n            \u003ctd valign=\"top\"\u003e\u003cfont\u003eConsequences of system downtime are not only limited to equipment replacement. Additional losses can result from lost orders, idle workers, overtime, customer\/management dissatisfaction, expedited freight charges and expedited shipping costs.\u003c\/font\u003e\u003c\/td\u003e\n\n        \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cfont\u003e\u003cfont\u003e\u003cspan class=\"style60\"\u003eRecommend Practices\u003c\/span\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003c\/font\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003cspan class=\"style63 style64\"\u003e\u003cfont\u003e\u003cfont\u003e\u003cstrong\u003e1) Earthing System\u003c\/strong\u003e\u003cbr\u003e\n\nSurge Protectors shunt transients to the earth grounding system. A low impedance ground path, at the same potential, is critical for the surge protectors to function properly. All power systems, communication lines, grounded and ungrounded metallic objects need to be equipotentially bonded for the protection scheme to work efficiently.\u003c\/font\u003e\u003c\/font\u003e\u003cstrong\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cfont\u003e2) Underground Connection from External PV Array to Electrical Control Equipment\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n\u003cfont\u003eIf possible, the connection between the external Solar PV Array and the internal power control equipment should be underground or electrically shielded to limit the risk of direct lightning strikes and\/or coupling.\u003cbr\u003e\n\n\u003cbr\u003e\n\n\u003cstrong\u003e3) Coordinated Protection Scheme\u003c\/strong\u003e\u003cbr\u003e\n\nAll available power and communication networks should be addressed with surge protection to eliminate PV system vulnerabilities. This would include the primary AC utility power supply, Inverter AC output, Inverter DC input, PV string combiner and other related data\/signal lines such as RS-485, 4-20mA current loop, PT-100, RTD, and telephone modems.\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":51347903775030,"sku":"053-04210","price":108.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/ds240.jpg?v=1732917902"},{"product_id":"4-0-5-red-battery-inverter-cable-2-lugs","title":"4\/0 5' Red Battery Inverter Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e4\/0 5' Red Battery Inverter Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3\/8\" diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing. Cables are marked in red heat-shrink tubing for positive and white heat-shrink on black wire for negative.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904168246,"sku":"052-04005-R","price":109.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Untitleddesign_83_05e1ecc2-19ee-48ba-a1ae-4ae84a17af70.jpg?v=1760991261"},{"product_id":"4-0-5-black-battery-inverter-cable-2-lugs","title":"4\/0 5' Black Battery Inverter Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e4\/0 5' Black Battery Inverter Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3\/8\" diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing. Cables are marked in red heat-shrink tubing for positive and white heat-shrink on black wire for negative.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904332086,"sku":"052-04005-B","price":109.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/Untitleddesign_83_1d840677-5620-482d-8a09-ad5dd3b40a72.jpg?v=1760989897"},{"product_id":"4-0-10-black-battery-inverter-cable-2-lugs","title":"4\/0 10' Black Battery Inverter Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e4\/0 10' Black Battery Inverter Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUse these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3\/8\" diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing. Cables are marked in red heat-shrink tubing for positive and white heat-shrink on black wire for negative.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904397622,"sku":"052-04010-B","price":192.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/battinvertcable_919083c2-36d5-4adc-8532-6ae2e554b210.jpg?v=1732917909"},{"product_id":"4-0-10-red-battery-inverter-cable-2-lugs","title":"4\/0 10' Red Battery Inverter Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e4\/0 10' Red Battery Inverter Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUse these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3\/8\" diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing. Cables are marked in red heat-shrink tubing for positive and white heat-shrink on black wire for negative.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904430390,"sku":"052-04010-R","price":192.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/battinvertcable_55a49953-2238-47dd-8d43-c95026c48307.jpg?v=1732917910"},{"product_id":"2-0-10-red-battery-inverter-cable-2-lugs","title":"2\/0 10' Red Battery Inverter Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e2\/0 10' Red Battery Inverter Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUse these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3\/8\" diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing. Cables are marked in red heat-shrink tubing for positive and white heat-shrink on black wire for negative.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904463158,"sku":"052-02010-R","price":82.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/battinvertcable_ece9fd0d-d1de-49c4-90de-d32687cc18b8.jpg?v=1732917910"},{"product_id":"2-0-10-black-battery-inverter-cable-2-lugs","title":"2\/0 10' Black Battery Inverter Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e2\/0 10' Black Battery Inverter Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUse these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3\/8\" diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing. Cables are marked in red heat-shrink tubing for positive and white heat-shrink on black wire for negative.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904561462,"sku":"052-02010-B","price":82.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/battinvertcable_29679c6d-be48-4b9b-8031-b5620ba2f759.jpg?v=1732917913"},{"product_id":"2-0-5-black-battery-inverter-cable-2-lugs","title":"2\/0 5' Black Battery Inverter Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e2\/0 5' Black Battery Inverter Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUse these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3\/8\" diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing. Cables are marked in red heat-shrink tubing for positive and white heat-shrink on black wire for negative.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904594230,"sku":"052-02005-B","price":49.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/battinvertcable_ab6adf82-363b-4306-a258-d2e2537090eb.jpg?v=1732917913"},{"product_id":"2-0-5-red-battery-inverter-cable-2-lugs","title":"2\/0 5' Red Battery Inverter Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e2\/0 5' Red Battery Inverter Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUse these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3\/8\" diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing. Cables are marked in red heat-shrink tubing for positive and white heat-shrink on black wire for negative.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904626998,"sku":"052-02005-R","price":49.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/battinvertcable_fe1ca311-2f89-44ff-a45e-c79a9db4095a.jpg?v=1732917914"},{"product_id":"4-0-awg-8-black-battery-interconnect-cable-2-lugs","title":"4\/0 AWG 8\" Black Battery Interconnect Cable 2 lugs","description":"\u003cp\u003e\n\n\t\u003cstrong\u003e4\/0 AWG 8\" Black Battery Interconnect Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003e\n\n\tUse these cables between individual battery cells or between battery banks. Circuits protected by 250-amp breakers or 400-amp fuses should use 4\/0 cables. Use 2\/0 cables for 175-amp breakers and 200-amp fuses. Use #2 cables for 110-amp or smaller fuses or breakers. Cables with 1 red end and 1 black end are used for series battery interconnects. Cables with white ends are for negative battery parallel jumpers.\u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904921910,"sku":"052-05145-B","price":16.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/batteryinterconnects.jpg?v=1732917917"},{"product_id":"4-0-awg-18-black-battery-interconnect-cable-2-lugs","title":"4\/0 AWG 18\" Black Battery Interconnect Cable 2 lugs","description":"\u003cp\u003e\u003cstrong\u003e4\/0 AWG 18\" Black Battery Interconnect Cable 2 lugs\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"main-text\"\u003eUse these cables between individual battery cells or between battery banks. Circuits protected by 250-amp breakers or 400-amp fuses should use 4\/0 cables. Use 2\/0 cables for 175-amp breakers and 200-amp fuses. Use #2 cables for 110-amp or smaller fuses or breakers. Cables with 1 red end and 1 black end are used for series battery interconnects. Cables with white ends are for negative battery parallel jumpers.\u003c\/p\u003e","brand":"AEE Solar","offers":[{"title":"Default Title","offer_id":51347904954678,"sku":"052-05142-B","price":50.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/files\/batteryinterconnects_7f7f987e-d50d-40a9-8b3b-d36cb08c9c0c.jpg?v=1732917917"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/2233\/8102\/collections\/ED-SQD-053-02423-group.jpg?v=1739985934","url":"https:\/\/thesolarstore.com\/collections\/electrical-accessories.oembed?page=4","provider":"The Solar Store","version":"1.0","type":"link"}