Aurora PVI Transformerless Inverter PVI-5000-OUTD-US-A

Aurora PVI Transformerless Inverter PVI-5000-OUTD-US-A

Model: 030-09709

Brand: Power-One

Price: $1,995.00 


Aurora PVI Transformerless Inverter PVI-5000-OUTD-US-A

Power-One Aurora PVI Transformerless Inverters

The Aurora PVI series are some of the most flexible string inverters available. PVI inverters have two separate MPPT inputs, allowing for two sub-arrays to be configured with differing string lengths, orientations, or even different PV modules. Conditions on one MPPT will not affect the other. Additionally, the PVI inverters have two input terminals for each separate MPPT section allowing as many as four strings of modules (two on each MPPT) to be connected without separate string fusing. Both MPPT inputs can also be paralleled for use with a single array. A wide input voltage range allows for smaller installations with reduced string sizes where needed.

An integrated LCD displays real-time operating parameters, and RS-485 and USB interfaces can connect remote monitoring systems. An integrated DC disconnect is standard on all “S” models (models without a DC disconnect are available by special order). Aurora PVI inverters can produce full-rated power at
ambient temperatures up to 122°F (50°C). The fan-less design and NEMA 4X enclosure provide a water and airtight seal. Output voltage can be set for 240 VAC split-phase, or 208 VAC or 277 VAC (480 VAC WYE) for 3-phase systems (3 inverters required for phase balancing). All PVI inverters are Listed to UL 1741/IEEE1547 and CSA-C22.2 N.107.1-01 for the U.S. and Canada, and come with a 10-year warranty, which is extendable to 15 or 20 years.

Tech Tip:

With transformerless inverters, all PV array wiring must be PV Wire, and any separate DC string combiners or disconnects used must provide for fusing or switching on both the positive and negative conductors.

Power-One's Aurora transformerless single-phase inverters are available in sizes covering most common residential requirements, and can be used in groups of 3 for commercial 3-phase applications. The transformerless design reduces internal power losses for high efficiencies. Output voltage can be set to 240 VAC split-phase, or 208 VAC or 277 VAC (480 VAC WYE) for three-phase systems. The 3.0 through 4.2 kW units have dimensions of 33.75"H x 12.75"W x 8.7"D, including the DC disconnect. The 5 and 6 kW units are taller, with a height of 41.4" and weigh 60lbs

Features:

  • Internal Arc Fault Circuit Interrupter (AFCI) for added safety per NEC 2011
  • Field selectable 208, 240 or 277 VAC output
  • RS485 Communications interface included
  • Operating temperatures of -13 °F to +131°F (-25 °C to +55°C)
  • Active and reactive power control, low voltage ride-through
  • Available in sizes from 3 kW to 12 kW
  • Field configureable for either positive or negative ground PV arrays
  • 10-year warranty, extendable up to 20 years
  • Listed to UL 1741-2010 for U.S. and Canada
  • Compliant with:
    • IEEE 1547-2003
    • IEEE 1547.1
    • UL1699B-2013
    • ANSI/IEEE C62.41
    • FCC Part 15 A& B
    • C22. 2 No. 107.1-01 (Sept. 2011)



    Model
    Max AC Output
    DC array voltage
    MPPT range
    CEC efficiency
    Max AC current
    Weight
    Item Code
    208V
    240V
    277V
    PVI-3.0-OUTD-US-A
    3,000 W

    140 to 600 VDC

    200 to 530 VDC
    96%
    14.5 A
    12.0 A
    47 lb
    030-09705
    PVI-3.6-OUTD-US-A
    3,600 W
    17.2 A
    16.0 A
    47 lb
    030-09706
    PVI-3.8-OUTD-US
    3,800 W
    16.0 A
    47 lb
    030-09707
    PVI-4.2-OUTD-US-A
    4,200 W
    20.0 A
    47 lb
    030-09708
    PVI-5000-OUTD-US-A
    5,000 W
    96.5%
    27 A
    23 A
    20 A
    60 lb
    030-09709
    PVI-6000-OUTD-US-A
    6,000 W
    30A
    28 A
    24 A
    60 lb
    030-09710

 