Xantrex XW6048-120/240-60 6000 Watt 48 V XW Series Hybrid Inverter-Charger
The Xantrex XW Series hybrid inverter/charger offers an innovative, integrated design which minimizes external balance-of-system components allowing for much quicker and easier installation. The XW Series offers pure sine-wave capability as well as split-phase operation right out of the box for 120 VAC and/or 240 VAC solutions. Up to three units can be operated in parallel, offering 18 kW, 120/240 VAC power.
Certified to UL-1741 and CSA for grid-tie applications, the XW can be used as a grid-tie battery-backup inverter or an off-grid inverter. One or two XW MPPT charge controllers are required for PV grid-tie operation.
Unsurpassed surge capacity is achieved by using digital control to regulate the output voltage from dropping during surge. A full 200% rated output power is delivered to load under surge conditions. Efficient, power-factor-corrected, high-current multi-stage battery charging minimizes recharge time and electricity/fuel costs, and prolongs battery life.
The inverter display panel give status-at-a-glance. LEDs indicate AC-in status, faults/warnings, equalize mode, and battery state of charge. Three-character LCD indicates output power or charge current.
The new wall-mount design is easier to install than the SW power panel. The power distribution panel includes all AC/DC disconnects and wiring so there is no need to individually purchase separate components. The distribution panel and conduit box is factory wired and labeled to support one inverter in a code-compliant manner, and it has wiring space and conduit and breaker knockouts to add up to three inverters and/or four charge controllers. Field-reversible door with magnetic catch makes access to wiring easy. Options include an XW connection kit for a second inverter, an XW conduit box for systems with more than two inverters or to retrofit XW inverters into existing systems which already have AC/DC disconnects. Conduit box/raceway has barriers to ensure separation between low-voltage communication cables and AC and DC wires.
XW-MPPT60-150 60A Solar Charge Controller with integrated PV ground fault protection accepts arrays with open-circuit voltage up to 150 VAC and employs dynamic maximum power point tracking. The XW system control panel plugs into Xanbus network and provides a central user interface to configure and monitor all components in the system.
5-year warranty. Dimensions of the inverter are 16" x 23" x 9". The inverter is field-serviceable without needing to remove it from the wall.
XW Series Inverter / Charger Features:
True sine wave output
120/240 volt AC spilt-phase operation
Dual AC inputs
Integrated design to minimize external balance-of-system components
XanBus enabled network communication
Certified to UL1741 and CSA for utility-interactive applications
Unprecedented surge capacity
Efficient, power factor corrected, high-current, multistage battery charging
Xantrex XW true sine wave inverter
features comparison chart
Model
Price |
XW6048
|
XW4548
|
XW4024
|
| Continuous output power |
6,000W |
4,500W |
4,000W |
| Surge rating (10 second) |
12,000W |
9,000W |
8,000W |
| Low load efficiency |
95% |
95% |
95% |
| Idle consumption search mode |
<8W |
<8w |
<8w |
| AC connections |
AC1(grid)
AC2(generator) |
AC1(grid)
AC2(generator) |
AC1(grid)
AC2(generator) |
| AC voltage |
120/240Vac
split phase |
120/240Vac
split phase |
120/240Vac
split phase |
| AC input breaker |
60A 2 pole |
60A 2 pole |
60A 2 pole |
| Utility interactive |
yes |
yes |
yes |
| CEC weighted efficiency |
92.5% |
93% |
91% |
| CEC power rating |
5752W |
4500W |
4000W |
| AC output voltage |
L-N:120Vac +/- 3%; L-L:240Vac +/- 3% |
| AC output frequency |
60+/-0.1Hz |
60+/-0.1Hz |
60+/-0.1Hz |
| DC current at rated power |
130A |
96A |
178A |
| Total harmonic distortion |
<5% |
<5% |
<5% |
| Automatic transfer relay |
60A |
60A |
60A |
| Typical transfer time |
8ms |
8ms |
8ms |
| Maximum continuous charge rate |
89.4% |
90.2% |
85.8% |
| Multiple unit configurations |
Up to 3 parallel units in 120/240V split phase config. |
| Auxiliary relay output |
0-12V DC, maximum 250 mA DC |
| Non-volatile memory |
yes |
yes |
yes |
| System network |
Xanbus™
(publish-subscribe network, no need for hubs or special cards) |
| Mounting |
wall mount, backplate included |
| Dimensions (HxWxD) |
23"x16"x9" |
23"x16"x9" |
23"x16"x9" |
| Weight |
125 lb. |
115 lb. |
115 lb. |
| Shipping weight |
132 lb. |
122 lb. |
122 lb. |
| Display panel |
Status LEDs indicate AC-in status, faults/warnings, equalize mode, battery level. 3 Character display indicates output power or charge current, fault/warning codes. On/off and equalize buttons. |
| Battery temp. sensor |
included |
included |
included |
| Operational temp. range |
-13 to 158°F |
-13 to 158°F |
-13 to 158°F |
| Standard warranty |
5 years |
5 years |
5 years |
|