Powercom SLK-4000 Solar King (SLK-4000-UL) 240V 4000W Sine Wave PV Inverter - Retail
Manufacturer: Powercom USA
MFR Part #:SLK-4000
Condition: New
Packaging: Retail
Description
The most advanced grid-tie PV inverter in the world. Converting sun light into electricity energy for home / industrial applications, and powering up our world with free solar energy is now no longer just a dream.
Features
Anti-Islanding detection methods: Frequency, voltage and utility impedance.
Build-in MPPT (Maximum Power Point Tracking) function.
High efficiency with wide range operation.
Design to meet UL-1741 or CSA Std.C22.2 No.107.1-01 requirements.
Easy assembly in production line.
Easy replacement when servicing. The mean time of service is less than 20 minutes.
Firmware flash capability: The firmware inside the micro-controllers can be updated by optional communication interface.
GFCI: Ground Fault Current Interruption, which is also known as RCD (Residual Current Device). To prevent electrical hazard of user, a current transformer monitoring the difference between L and N current is applied. When the current difference is larger than specified value stated in section “General Data”, inverter will cut its output to grid.
Bundled software for user buying optional communication card.
UL1741 certified.
Specs
| Input Data |
|
| Maximum Input Power |
5000W |
| Nominal DC voltage |
360V~400V |
Max. input voltage
Maximum PV open voltage |
450VDC |
| MPPT voltage range |
150V to 450V +/-5% |
| Working voltage range |
100 +/-5% ~ 450-5%+0%V |
| Initial feeding voltage |
150V +/-5% |
| Full rating working range |
250V to 450V |
| Max. input current |
20ADC |
| Shutdown voltage |
80V typical |
| DC voltage ripple |
< 10% |
| DC insulation resistance |
> 8M ohm |
| DC Switch |
On/Off 20A |
| DC Connector |
Terminal block |
| Output data |
|
| Nominal output power |
4000W |
| Operational Voltage range 1 |
183V~228V @208Vac
211V~264V @240Vac |
| Operational Normal voltage |
59.3~60.5 for 60Hz 2
59.5~60.5 for 60Hz 3 |
| Nominal output frequency |
60Hz |
| Maximum input short circuit current |
<30A |
| Maximum output over current protection |
<37.5A |
| Synchronization in rush current 208Vac |
<28.3A |
| Synchronization in rush current 240Vac |
<24.6A |
| Nominal output current 208Vac |
19.2A |
| Nominal output current 240Vac |
16.7A |
| O/P current distortion 4 |
THD<5%, each harmonics <3% |
| DC current injection |
<0.5% of rated inverter output current |
| General Data |
|
| Internal power consumption |
< 7W |
| Standby power (at night) |
< 0.1W |
| Minimum conversion efficiency (DC/AC) |
>90%
Under input voltage>210V, load >20% |
| Maximum Conversion Efficiency (DC/AC) 5 |
>96% |
| CEC Efficiency |
>94.5% |
| Maximum output fault current and duration |
<100A , Duration time < 80m sec |
| Ground current detection frequency |
0~700Hz |
| Protection degree |
NEMA 3R (rain proof) |
| Operation temperature |
-25 to 45°C
-25~+40°C full rating output
About +40°C output de-rating
|
| Heat Dissipation |
Convection |
| Acoustic noise level |
<40dB, A-weighted, frequency up to 20kH |
| Altitude |
Up to 3000m without power derating,
5°C derated for each additional 500m
|
| Weight |
53lbs. |
1. UL-1741, it is -12%/ +10%
2. Based on the limit of IEEE1547
3. Based on limit of CSA Std. C22.2 No. 107.1-01
4. Under utility voltage THD<3%, reference IEEE1547, EN61000-3-2
5. Under input voltage>=400V, full rated output power, 25oC ambient
6. According to UL-1741 requirement
|